Arc Flash Rated Harness

Product Description

Our ASTM F887-certified Arc Flash Rated Harness features Kevlar®/Nomex® dual-weave or arc-rated nylon webbing — tested at 40 cal/cm² arc flash exposure with zero ignition, melting, or dripping — followed by mandatory post-arc drop testing per ANSI/ASSP Z359 to verify mechanical fall arrest integrity is fully retained after arc flash exposure, engineered for live electrical, utility, and oil & gas operations across the UAE, GCC, Middle East, and Africa.

Key Features:

  • 40 cal/cm² Arc Flash Exposure Tested — Full harness tested per ASTM F887 at 40 cal/cm² with zero ignition, melt, or drip per ASTM F2621 mannequin test method
  • Post-Arc Drop Test Certified — Harness retains full mechanical fall arrest integrity following arc flash exposure per ANSI/ASSP Z359 drop test protocol
  • Kevlar®/Nomex® or Arc-Rated Nylon Webbing — Inherently flame-resistant webbing maintaining structural integrity at 7,000 lbf minimum breaking strength post-arc exposure
  • Dielectric Hardware Rated to 35 kV — All D-rings and buckles rated for 35,000V dielectric withstand for live electrical working environments
  • Dorsal & Sternal D-Ring Attachment — Dual attachment points for fall arrest and rope access connection in multi-hazard electrical environments
  • OSHA 1910.269 Compliant — Mandatory compliance standard for workers exposed to arc flash hazards in electrical power generation and distribution operations

Additional Information

Specifications:

Standards: ASTM F887-20 | EN 361:2002 | ANSI/ASSE Z359.11 | OSHA 1910.269

Arc Flash Rating: Tested at 40 cal/cm² — no melting, dripping, or ignition; self-extinguishes within 5 seconds

Webbing: Polyamide or Kevlar®/Nomex® — minimum breaking strength 7,000 lbf (31.1 kN)

Post-Arc Drop Test: Passes ANSI Z359 dynamic drop test at 282 lb (128 kg) after 40±5 cal/cm² arc exposure

D-Ring Configuration: 1 dorsal (fall arrest) + optional sternal and side D-rings — dielectric hardware — model dependent

Max Arrest Force: ≤ 1,800 lbf (8 kN) per ANSI Z359.11 fall arrest requirements

Approved Brands: 3M DBI-SALA, KARAM, Miller & other UAE-certified manufacturers

You May Also Like

FFP3 Disposable Respirator

Welding Goggles

Welding Helmet

Chemical Resistant Goggles

Clear Lens EN 166

Full Brim Helmet

Lifestyle brand by Protrade Partners

Enquire About This Product

Fill out the form below, and our team will get back to you with all the details you need. We’re here to help you make the best choice for your workwear needs!